Skip to content

Monostable

Symbol

Description

The "Q" output is set to one after the rising edge of the "Rising" input or the falling edge of the "Falling" input. The "notQ" output is the complement of "Q". The "Width" input controls the pulse width in seconds.

Important

Non-zero inputs are treated as 1

Library

Control > Logic

Parameters

Property Display Name Parameter Type Description
SamplingTime Sampling Time [s] DoubleParameter Sampling Time

Pins

Property Pin Name Type Description
Rising Rising ControlIn Rising edge input
Falling Falling ControlIn Falling edge input
PulseWidth PulseWidth ControlIn Pulse width input (in s)
Q Q ControlOut Output
notQ notQ ControlOut Output Complement (!Q)

Default Size

Width Height
4 6