Monostable

Description
The "Q" output is set to one after the rising edge of the "Rising" input or the falling edge of the "Falling" input. The "notQ" output is the complement of "Q". The "Width" input controls the pulse width in seconds.
Important
Non-zero inputs are treated as 1
Library
Control > Logic
Parameters
| Property | Display Name | Parameter Type | Description |
|---|---|---|---|
| SamplingTime | Sampling Time [s] | DoubleParameter | Sampling Time |
Pins
| Property | Pin Name | Type | Description |
|---|---|---|---|
| Rising | Rising | ControlIn | Rising edge input |
| Falling | Falling | ControlIn | Falling edge input |
| PulseWidth | PulseWidth | ControlIn | Pulse width input (in s) |
| Q | Q | ControlOut | Output |
| notQ | notQ | ControlOut | Output Complement (!Q) |
Default Size
| Width | Height |
|---|---|
| 4 | 6 |